LARGEST PORTFOLIO OF
50+ Lyophilized Real-time PCR syndromic multiplexes
Largest Menu of Lyophilized Infectious Disease Assays
LARGEST PORTFOLIO OF
LMP product configurations have a minimum 4-week lead time.
Largest Menu of Lyophilized Infectious Disease Assays
Easy, fast & effective
Multi-platform compatibility with QuantStudio™ 5, ABI 7500 Fast Dx, Bio-Rad CFX96 Touch™, Bio-Rad CFX384 Touch™ and BD MAX™
Long-term shelf life stability
PIXL™ REAL-TIME PCR PLATFORM
Compatibility
650-Series-PXL
For PIXL™ compatible Real-time PCR syndromic multiplexes, reference the 650-Series-PXL product number when placing your order.
BD MAX™ Compatibility
450-Series-MAX
For BD MAX™ compatible Real-time PCR syndromic multiplexes, reference the 450-Series-MAX product number when placing your order.
Multi-Platform Compatibility
450-Series-LMP
For multi-platform Real-time PCR syndromic multiplex compatible with ABI 7500 Fast, QuantStudio™ & Bio-Rad CFX Touch™, reference the 450-Series-LMP product number when placing your order.
vanA, vanB, vanC1, vanC2/3 Part no. 450-016-Series
BioGX real-time PCR-based detection reagents are manufactured and packaged as open system reagents (OSR) for use with open system platforms and have to be validated by the user. Examples of open system platforms are the BD MAX™ System, Applied Biosystems QuantStudio™ 5, and Bio-Rad CFX96 Touch™ real-time PCR platforms.
Research use only reagents are not intended for human or animal diagnostic use. It is the responsibility of the end user to determine the performance of the reagents in an appropriately designed validation study for their intended use.
vanA, vanB Part no. 450-017-Series
BioGX real-time PCR-based detection reagents are manufactured and packaged as open system reagents (OSR) for use with open system platforms and have to be validated by the user. Examples of open system platforms are the BD MAX™ System, Applied Biosystems 7500 Fast Dx, QuantStudio™ 5, Bio-Rad CFX96 Touch™ and Bio-Rad CFX384 Touch™real-time PCR platforms.
Research use only reagents are not intended for human or animal diagnostic use. It is the responsibility of the end user to determine the performance of the reagents in an appropriately designed validation study for their intended use.
KPC, NDM, OXA-48 Part no. 450-018-Series
BioGX real-time PCR-based detection reagents are manufactured and packaged as open system reagents (OSR) for use with open system platforms and have to be validated by the user. Examples of open system platforms are the BD MAX™ System, Applied Biosystems QuantStudio™ 5, and Bio-Rad CFX96 Touch™ real-time PCR platforms.
Research use only reagents are not intended for human or animal diagnostic use. It is the responsibility of the end user to determine the performance of the reagents in an appropriately designed validation study for their intended use.
VIM, GES, mcr-1 Part no. 450-019-Series
BioGX real-time PCR-based detection reagents are manufactured and packaged as open system reagents (OSR) for use with open system platforms and have to be validated by the user. Examples of open system platforms are the BD MAX™ System, Applied Biosystems QuantStudio™ 5, and Bio-Rad CFX96 Touch™ real-time PCR platforms.
Research use only reagents are not intended for human or animal diagnostic use. It is the responsibility of the end user to determine the performance of the reagents in an appropriately designed validation study for their intended use.
vanA, vanB, mecA Part no. 450-081-LMP
BioGX real-time PCR-based detection reagents are manufactured and packaged as open system reagents (OSR) for use with open system platforms and have to be validated by the user. Examples of open system platforms are Applied Biosystems QuantStudio™ 5, and Bio-Rad CFX96 Touch™ real-time PCR platforms.
Research use only reagents are not intended for human or animal diagnostic use. It is the responsibility of the end user to determine the performance of the reagents in an appropriately designed validation study for their intended use.
Plasmodium spp., Plasmodium falciparum, Plasmodium vivax, RNase P Part no. 450-032-Series
BioGX real-time PCR-based detection reagents are manufactured and packaged as open system reagents (OSR) for use with open system platforms and have to be validated by the user. Examples of open system platforms are the BD MAX™ System, Applied Biosystems QuantStudio™ 5, and Bio-Rad CFX96 Touch™ real-time PCR platforms.
Research use only reagents are not intended for human or animal diagnostic use. It is the responsibility of the end user to determine the performance of the reagents in an appropriately designed validation study for their intended use.
Anaplasma phagocytophilium, Babesia microti, Ehrlichia spp. Part no. 450-033-Series
BioGX real-time PCR-based detection reagents are manufactured and packaged as open system reagents (OSR) for use with open system platforms and have to be validated by the user. Examples of open system platforms are the BD MAX™ System, Applied Biosystems QuantStudio™ 5, and Bio-Rad CFX96 Touch™ real-time PCR platforms.
Research use only reagents are not intended for human or animal diagnostic use. It is the responsibility of the end user to determine the performance of the reagents in an appropriately designed validation study for their intended use.
SARS-CoV-2, Flu A, Flu B, RSV Part no. 450-015-Series
BioGX real-time PCR-based detection reagents are manufactured and packaged as open system reagents (OSR) for use with open system platforms and have to be validated by the user. Examples of open system platforms are the BD MAX™ System, and Applied Biosystems QuantStudio™ 5 real-time PCR platforms.
Research use only reagents are not intended for human or animal diagnostic use. It is the responsibility of the end user to determine the performance of the reagents in an appropriately designed validation study for their intended use.
SARS-CoV-2 (N1), Flu A, Flu B, RSV Part no. 450-066-H-HMP
BioGX real-time PCR-based detection reagents are manufactured and packaged as open system reagents (OSR) for use with open system platforms and have to be validated by the user. Examples of open system platforms are the Applied Biosystems QuantStudio™ 5 and ABI 7500 Fast Dx real-time PCR platforms.
Research use only reagents are not intended for human or animal diagnostic use. It is the responsibility of the end user to determine the performance of the reagents in an appropriately designed validation study for their intended use.
SARS-CoV-2 N1, RNase P & SARS-CoV-2 N2, RNase P Part no. 500-001-C-MAX-R
The SARS-CoV-2 N1, RNase P and SARS-CoV-2 N2, RNase P real-time PCR-based detection reagent is manufactured and packaged as an open system reagent (OSR) for use with open system platforms and has to be validated by the user. An example of an open system platform is the BD MAX™ System.
Research use only reagents are not intended for human or animal diagnostic use. It is the responsibility of the end user to determine the performance of the reagents in an appropriately designed validation study for their intended use.
Xfree™ SARS-CoV-2-XMP Extraction-Free Direct PCR -Multi-Platform Part no. 450-001-XMP
BioGX real-time PCR-based detection reagents are manufactured and packaged as open system reagents (OSR) for use with open system platforms and have to be validated by the user. Examples of open system platforms are the Applied Biosystems 7500 Fast Dx, QuantStudio™ 5, Bio-Rad CFX96 Touch™ and Bio-Rad CFX384 Touch™ real-time PCR platforms.
Research use only reagents are not intended for human or animal diagnostic use. It is the responsibility of the end user to determine the performance of the reagents in an appropriately designed validation study for their intended use.
Xfree™ SARS-CoV-2-XMP Extraction-Free Direct PCR - Multi-Platform (Cy 5.5) Part no. 450-065-XMP
BioGX real-time PCR-based detection reagents are manufactured and packaged as open system reagents (OSR) for use with open system platforms and have to be validated by the user. Examples of open system platforms are the Applied Biosystems QuantStudio™ 5 and Bio-Rad CFX96 Touch™ real-time PCR platforms.
Research use only reagents are not intended for human or animal diagnostic use. It is the responsibility of the end user to determine the performance of the reagents in an appropriately designed validation study for their intended use.
Xfree™ SARS-CoV-2 (N1, RdRp), RNase P, IAC Extraction-Free PCR - Multi-Platform Open System PCR Reagents Part no. 450-085-XMP
BioGX real-time PCR-based detection reagents are manufactured and packaged as open system reagents (OSR) for use with open system platforms and have to be validated by the user. Examples of open system platforms are the Applied Biosystems 7500 Fast Dx, QuantStudio™ 5, Bio-Rad CFX96 Touch™, Bio-Rad CFX384 Touch™ and BioGX pixl.16 real-time PCR platforms.
Research use only reagents are not intended for human or animal diagnostic use. It is the responsibility of the end user to determine the performance of the reagents in an appropriately designed validation study for their intended use.
Xfree™ COVID-19, Flu A, Flu B Part no. 450-090-H-PXL
The BioGX Xfree™ COVID-19, Flu A, Flu B PCR Assay is offered in the lyophilized “Just Add Sample” format within single PCR tubes where no other reagent is required. The test is available for Applied Biosystems 7500 Fast Dx, QuantStudio™ 5, Bio-Rad CFX96 Touch™, Bio-Rad CFX384 Touch™ and BioGX pixl.16 real-time PCR platforms. Nucleic acid extraction is not needed, and the lyophilized PCR reagents are simply rehydrated and patient sample is directly added. The fast and simple workflow is designed to help laboratories to increase their testing capacity without adding expert molecular staff or new automation.
* This product is for Research Use Only.
Campylobacter spp., Shigella spp., Salmonella spp. Part no. 450-020-Series
BioGX real-time PCR-based detection reagents are manufactured and packaged as open system reagents (OSR) for use with open system platforms and have to be validated by the user. Examples of open system platforms are the BD MAX™ System, Applied Biosystems QuantStudio™ 5, and Bio-Rad CFX96 Touch™ real-time PCR platforms.
Research use only reagents are not intended for human or animal diagnostic use. It is the responsibility of the end user to determine the performance of the reagents in an appropriately designed validation study for their intended use.
Escherichia coli O157, stx-1, stx-2 Part no. 450-021-Series
BioGX real-time PCR-based detection reagents are manufactured and packaged as open system reagents (OSR) for use with open system platforms and have to be validated by the user. Examples of open system platforms are the BD MAX™ System, Applied Biosystems QuantStudio™ 5, and Bio-Rad CFX96 Touch™ real-time PCR platforms.
Research use only reagents are not intended for human or animal diagnostic use. It is the responsibility of the end user to determine the performance of the reagents in an appropriately designed validation study for their intended use.
Cryptosporidium parvum, Giardia intestinalis, Entamoeba histolytica, Dientamoeba fragilis Part no. 450-022-Series
BioGX real-time PCR-based detection reagents are manufactured and packaged as open system reagents (OSR) for use with open system platforms and have to be validated by the user. Examples of open system platforms are the BD MAX™ System, Applied Biosystems QuantStudio™ 5, and Bio-Rad CFX96 Touch™ real-time PCR platforms.
Research use only reagents are not intended for human or animal diagnostic use. It is the responsibility of the end user to determine the performance of the reagents in an appropriately designed validation study for their intended use.
Cyclospora cayetenensis, Microsporidia (Encephalitozoon cuniculi, Encephalitozoon hellem, Encephalitozoon intestinalis, Enterocytozoon bieneusi) Part no. 450-023-Series
BioGX real-time PCR-based detection reagents are manufactured and packaged as open system reagents (OSR) for use with open system platforms and have to be validated by the user. Examples of open system platforms are the BD MAX™ System, Applied Biosystems 7500 Fast Dx, QuantStudio™ 5, Bio-Rad CFX96 Touch™ and Bio-Rad CFX384 Touch™ real-time PCR platforms.
Research use only reagents are not intended for human or animal diagnostic use. It is the responsibility of the end user to determine the performance of the reagents in an appropriately designed validation study for their intended use.
Campylobacter spp., Salmonella spp., Shigella spp., STEC (stx-1/stx-2) Part no. 450-061-Series
BioGX real-time PCR-based detection reagents are manufactured and packaged as open system reagents (OSR) for use with open system platforms and have to be validated by the user. Examples of open system platforms are the BD MAX™ System, Applied Biosystems QuantStudio™ 5, and Bio-Rad CFX96 Touch™ real-time PCR platforms.
Research use only reagents are not intended for human or animal diagnostic use. It is the responsibility of the end user to determine the performance of the reagents in an appropriately designed validation study for their intended use.
Microsporidia (Encephalitozoon cuniculi, Encephalitozoon hellem, Encephalitozoon intestinalis, Enterocytozoon bieneusi) Part no. 450-063-Series
BioGX real-time PCR-based detection reagents are manufactured and packaged as open system reagents (OSR) for use with open system platforms and have to be validated by the user. Examples of open system platforms are the BD MAX™ System, Applied Biosystems QuantStudio™ 5, and Bio-Rad CFX96 Touch™ real-time PCR platforms.
Research use only reagents are not intended for human or animal diagnostic use. It is the responsibility of the end user to determine the performance of the reagents in an appropriately designed validation study for their intended use.
BK Virus Part no. 450-026-Series
BioGX real-time PCR-based detection reagents are manufactured and packaged as open system reagents (OSR) for use with open system platforms and have to be validated by the user. Examples of open system platforms are the BD MAX™ System, Applied Biosystems 7500 Fast Dx, QuantStudio™ 5, Bio-Rad CFX96 Touch™ and Bio-Rad CFX384 Touch™ real-time PCR platforms.
Research use only reagents are not intended for human or animal diagnostic use. It is the responsibility of the end user to determine the performance of the reagents in an appropriately designed validation study for their intended use.
CMV Part no. 450-027-Series
BioGX real-time PCR-based detection reagents are manufactured and packaged as open system reagents (OSR) for use with open system platforms and have to be validated by the user. Examples of open system platforms are the BD MAX™ System, Applied Biosystems 7500 Fast Dx, QuantStudio™ 5, Bio-Rad CFX96 Touch™ and Bio-Rad CFX384 Touch™ real-time PCR platforms.
Research use only reagents are not intended for human or animal diagnostic use. It is the responsibility of the end user to determine the performance of the reagents in an appropriately designed validation study for their intended use.
Enterovirus Part no. 450-006-Series
BioGX real-time PCR-based detection reagents are manufactured and packaged as open system reagents (OSR) for use with open system platforms and have to be validated by the user. Examples of open system platforms are the BD MAX™ System, Applied Biosystems 7500 Fast Dx, QuantStudio™ 5, Bio-Rad CFX96 Touch™ and Bio-Rad CFX384 Touch™ real-time PCR platforms.
Research use only reagents are not intended for human or animal diagnostic use. It is the responsibility of the end user to determine the performance of the reagents in an appropriately designed validation study for their intended use.
Epstein-Barr Virus Part no. 450-029-Series
BioGX real-time PCR-based detection reagents are manufactured and packaged as open system reagents (OSR) for use with open system platforms and have to be validated by the user. Examples of open system platforms are the BD MAX™ System, Applied Biosystems 7500 Fast Dx, QuantStudio™ 5, Bio-Rad CFX96 Touch™ and Bio-Rad CFX384 Touch™ real-time PCR platforms.
Research use only reagents are not intended for human or animal diagnostic use. It is the responsibility of the end user to determine the performance of the reagents in an appropriately designed validation study for their intended use.
Escherichia coli, Listeria spp., Streptococcus agalactiae Part no. 450-025-Series
BioGX real-time PCR-based detection reagents are manufactured and packaged as open system reagents (OSR) for use with open system platforms and have to be validated by the user. Examples of open system platforms are the BD MAX™ System, Applied Biosystems QuantStudio™ 5, and Bio-Rad CFX96 Touch™ real-time PCR platforms.
Research use only reagents are not intended for human or animal diagnostic use. It is the responsibility of the end user to determine the performance of the reagents in an appropriately designed validation study for their intended use.
HSV-1, HSV-2, VZV Part no. 450-030-Series
BioGX real-time PCR-based detection reagents are manufactured and packaged as open system reagents (OSR) for use with open system platforms and have to be validated by the user. Examples of open system platforms are the BD MAX™ System, Applied Biosystems QuantStudio™ 5, and Bio-Rad CFX96 Touch™ real-time PCR platforms.
Research use only reagents are not intended for human or animal diagnostic use. It is the responsibility of the end user to determine the performance of the reagents in an appropriately designed validation study for their intended use.
HSV-1, HSV-2, VZV, CMV Part no. 450-031-Series
BioGX real-time PCR-based detection reagents are manufactured and packaged as open system reagents (OSR) for use with open system platforms and have to be validated by the user. Examples of open system platforms are the BD MAX™ System, Applied Biosystems QuantStudio™ 5, and Bio-Rad CFX96 Touch™ real-time PCR platforms.
Research use only reagents are not intended for human or animal diagnostic use. It is the responsibility of the end user to determine the performance of the reagents in an appropriately designed validation study for their intended use.
JC Virus Part no. 450-028-Series
BioGX real-time PCR-based detection reagents are manufactured and packaged as open system reagents (OSR) for use with open system platforms and have to be validated by the user. Examples of open system platforms are the BD MAX™ System, Applied Biosystems 7500 Fast Dx, QuantStudio™ 5, Bio-Rad CFX96 Touch™ and Bio-Rad CFX384 Touch™ real-time PCR platforms.
Research use only reagents are not intended for human or animal diagnostic use. It is the responsibility of the end user to determine the performance of the reagents in an appropriately designed validation study for their intended use.
Neisseria meningitidis, Streptococcus pneumoniae, Haemophilus influenzae Part no. 450-024-Series
BioGX real-time PCR-based detection reagents are manufactured and packaged as open system reagents (OSR) for use with open system platforms and have to be validated by the user. Examples of open system platforms are the BD MAX™ System, Applied Biosystems QuantStudio™ 5, and Bio-Rad CFX96 Touch™ real-time PCR platforms.
Research use only reagents are not intended for human or animal diagnostic use. It is the responsibility of the end user to determine the performance of the reagents in an appropriately designed validation study for their intended use.
Dermatophyte spp., Fungus spp., Trichophyton rubrum Part no. 450-048-Series
BioGX real-time PCR-based detection reagents are manufactured and packaged as open system reagents (OSR) for use with open system platforms and have to be validated by the user. Examples of open system platforms are the BD MAX™ System, Applied Biosystems 7500 Fast Dx, QuantStudio™ 5, Bio-Rad CFX96 Touch™ and Bio-Rad CFX384 Touch™ real-time PCR platforms.
Research use only reagents are not intended for human or animal diagnostic use. It is the responsibility of the end user to determine the performance of the reagents in an appropriately designed validation study for their intended use.
Candida albicans, Candida glabrata, Candida krusei, Trichomonas vaginalis Part no. 450-035-Series
BioGX real-time PCR-based detection reagents are manufactured and packaged as open system reagents (OSR) for use with open system platforms and have to be validated by the user. Examples of open system platforms are the BD MAX™ System, Applied Biosystems 7500 Fast Dx, QuantStudio™ 5, Bio-Rad CFX96 Touch™ and Bio-Rad CFX384 Touch™ real-time PCR platforms.
Research use only reagents are not intended for human or animal diagnostic use. It is the responsibility of the end user to determine the performance of the reagents in an appropriately designed validation study for their intended use.
Adenovirus, Bordetella pertussis, Bordetella parapertussis Part no. 450-002-Series
BioGX real-time PCR-based detection reagents are manufactured and packaged as open system reagents (OSR) for use with open system platforms and have to be validated by the user. Examples of open system platforms are the BD MAX™ System, Applied Biosystems QuantStudio™ 5, and Bio-Rad CFX96 Touch™ real-time PCR platforms.
Research use only reagents are not intended for human or animal diagnostic use. It is the responsibility of the end user to determine the performance of the reagents in an appropriately designed validation study for their intended use.
Bordetella pertussis, B. parapertussis, B. holmesii, pertussis toxin Part no. 450-003-Series
BioGX real-time PCR-based detection reagents are manufactured and packaged as open system reagents (OSR) for use with open system platforms and have to be validated by the user. Examples of open system platforms are the BD MAX™ System, Applied Biosystems QuantStudio™ 5, and Bio-Rad CFX96 Touch™ real-time PCR platforms.
Research use only reagents are not intended for human or animal diagnostic use. It is the responsibility of the end user to determine the performance of the reagents in an appropriately designed validation study for their intended use.
Bordetella pertussis, B. parapertussis Part no. 450-004-Series
BioGX real-time PCR-based detection reagents are manufactured and packaged as open system reagents (OSR) for use with open system platforms and have to be validated by the user. Examples of open system platforms are the BD MAX™ System, Applied Biosystems 7500 Fast Dx, QuantStudio™ 5, Bio-Rad CFX96 Touch™ and Bio-Rad CFX384 Touch™ real-time PCR platforms.
Research use only reagents are not intended for human or animal diagnostic use. It is the responsibility of the end user to determine the performance of the reagents in an appropriately designed validation study for their intended use.
Coccidioides spp. Part no. 450-005-Series
BioGX real-time PCR-based detection reagents are manufactured and packaged as open system reagents (OSR) for use with open system platforms and have to be validated by the user. Examples of open system platforms are the BD MAX™ System, Applied Biosystems 7500 Fast Dx, QuantStudio™ 5, Bio-Rad CFX96 Touch™ and Bio-Rad CFX384 Touch™ real-time PCR platforms.
Research use only reagents are not intended for human or animal diagnostic use. It is the responsibility of the end user to determine the performance of the reagents in an appropriately designed validation study for their intended use.
Enterovirus Part no. 450-006-Series
BioGX real-time PCR-based detection reagents are manufactured and packaged as open system reagents (OSR) for use with open system platforms and have to be validated by the user. Examples of open system platforms are the BD MAX™ System, Applied Biosystems 7500 Fast Dx, QuantStudio™ 5, Bio-Rad CFX96 Touch™ and Bio-Rad CFX384 Touch™ real-time PCR platforms.
Research use only reagents are not intended for human or animal diagnostic use. It is the responsibility of the end user to determine the performance of the reagents in an appropriately designed validation study for their intended use.
Flu A, Flu B, RSV A/B Part no.450-014-Series
BioGX real-time PCR-based detection reagents are manufactured and packaged as open system reagents (OSR) for use with open system platforms and have to be validated by the user. Examples of open system platforms are the BD MAX™ System, Applied Biosystems QuantStudio™ 5, and Bio-Rad CFX96 Touch™ real-time PCR platforms.
Research use only reagents are not intended for human or animal diagnostic use. It is the responsibility of the end user to determine the performance of the reagents in an appropriately designed validation study for their intended use.
Flu A, Flu B, RSV A/B Part no. 450-070-HMP
The Flu A, Flu B, RSV A/B real-time PCR-based detection reagent is manufactured and packaged as an open system reagent (OSR) for use with open system platforms and has to be validated by the user. Examples of open system platforms are the Applied Biosystems QuantStudio™ 5, Applied Biosystems 7500 Fast Dx, Bio-Rad CFX96 Touch™ or CFX384 Touch™ real-time PCR platforms.
Research use only reagents are not intended for human or animal diagnostic use. It is the responsibility of the end user to determine the performance of the reagents in an appropriately designed validation study for their intended use.
Mycoplasma pneumoniae, Legionella spp., Chlamydia pneumoniae, Chlamydia psittaci Part no. 450-008-Series
BioGX real-time PCR-based detection reagents are manufactured and packaged as open system reagents (OSR) for use with open system platforms and have to be validated by the user. Examples of open system platforms are the BD MAX™ System, Applied Biosystems QuantStudio™ 5, and Bio-Rad CFX96 Touch™ real-time PCR platforms.
Research use only reagents are not intended for human or animal diagnostic use. It is the responsibility of the end user to determine the performance of the reagents in an appropriately designed validation study for their intended use.
Mycoplasma pneumoniae, Legionella pneumophila, Chlamydia pneumoniae, Pneumocystis jirovecii Part no. 450-009-Series
BioGX real-time PCR-based detection reagents are manufactured and packaged as open system reagents (OSR) for use with open system platforms and have to be validated by the user. Examples of open system platforms are the BD MAX™ System, Applied Biosystems QuantStudio™ 5, and Bio-Rad CFX96 Touch™ real-time PCR platforms.
Research use only reagents are not intended for human or animal diagnostic use. It is the responsibility of the end user to determine the performance of the reagents in an appropriately designed validation study for their intended use.
Mycoplasma pneumoniae, Legionella pneumophila, Chlamydia pneumoniae Part no. 450-007-Series
BioGX real-time PCR-based detection reagents are manufactured and packaged as open system reagents (OSR) for use with open system platforms and have to be validated by the user. Examples of open system platforms are the BD MAX™ System, Applied Biosystems QuantStudio™ 5, and Bio-Rad CFX96 Touch™ real-time PCR platforms.
Research use only reagents are not intended for human or animal diagnostic use. It is the responsibility of the end user to determine the performance of the reagents in an appropriately designed validation study for their intended use.
Mycobacterium tuberculosis Complex Part no. 450-010-Series
BioGX real-time PCR-based detection reagents are manufactured and packaged as open system reagents (OSR) for use with open system platforms and have to be validated by the user. Examples of open system platforms are the BD MAX™ System, Applied Biosystems 7500 Fast Dx, QuantStudio™ 5, Bio-Rad CFX96 Touch™ and Bio-Rad CFX384 Touch™ real-time PCR platforms.
Research use only reagents are not intended for human or animal diagnostic use. It is the responsibility of the end user to determine the performance of the reagents in an appropriately designed validation study for their intended use.
Mycobacterium tuberculosis complex, Mycobacterium avium complex, Mycobacterium spp. Part no. 450-054-Series
BioGX real-time PCR-based detection reagents are manufactured and packaged as open system reagents (OSR) for use with open system platforms and have to be validated by the user. Examples of open system platforms are the BD MAX™ System, Applied Biosystems 7500 Fast Dx, QuantStudio™ 5, Bio-Rad CFX96 Touch™ and Bio-Rad CFX384 Touch™ real-time PCR platforms.
Research use only reagents are not intended for human or animal diagnostic use. It is the responsibility of the end user to determine the performance of the reagents in an appropriately designed validation study for their intended use.
Pan-Aspergillus Part no. 450-011-Series
BioGX real-time PCR-based detection reagents are manufactured and packaged as open system reagents (OSR) for use with open system platforms and have to be validated by the user. Examples of open system platforms are the BD MAX™ System, Applied Biosystems 7500 Fast Dx, QuantStudio™ 5, Bio-Rad CFX96 Touch™ and Bio-Rad CFX384 Touch™ real-time PCR platforms.
Research use only reagents are not intended for human or animal diagnostic use. It is the responsibility of the end user to determine the performance of the reagents in an appropriately designed validation study for their intended use.
Pneumocystis jirovecii Part no. 450-012-Series
BioGX real-time PCR-based detection reagents are manufactured and packaged as open system reagents (OSR) for use with open system platforms and have to be validated by the user. Examples of open system platforms are the BD MAX™ System, Applied Biosystems 7500 Fast Dx, QuantStudio™ 5, Bio-Rad CFX96 Touch™ and Bio-Rad CFX384 Touch™ real-time PCR platforms.
Research use only reagents are not intended for human or animal diagnostic use. It is the responsibility of the end user to determine the performance of the reagents in an appropriately designed validation study for their intended use.
Streptococcus pyogenes Part no. 450-013-Series
BioGX real-time PCR-based detection reagents are manufactured and packaged as open system reagents (OSR) for use with open system platforms and have to be validated by the user. Examples of open system platforms are the BD MAX™ System, Applied Biosystems 7500 Fast Dx, QuantStudio™ 5, Bio-Rad CFX96 Touch™ and Bio-Rad CFX384 Touch™ real-time PCR platforms.
Research use only reagents are not intended for human or animal diagnostic use. It is the responsibility of the end user to determine the performance of the reagents in an appropriately designed validation study for their intended use.
Xfree™ Mycoplasma pneumoniae Open System PCR Reagents Part no. 450-093-E-PXL
The BioGX Xfree™ Mycoplasma pneumoniae PCR Assay is offered in the lyophilized “Just Add Sample” format within single PCR tubes where no other reagent is required. The test is available for BioGX pixl.16 real-time PCR instrument. Nucleic acid extraction is not needed, and the lyophilized PCR reagents are simply rehydrated and patient sample is directly added. The fast and simple workflow is designed to help laboratories to increase their testing capacity without adding expert molecular staff or new automation.
* This product is for Research Use Only.
Xfree™ Group A Streptococcus Part no. 450-092-PXL
The BioGX Xfree™ Group A Streptococcus PCR Assay is offered in the lyophilized “Just Add Sample” format within single PCR tubes where no other reagent is required. The test is available for Applied Biosystems 7500 Fast Dx, QuantStudio™ 5, Bio-Rad CFX96 Touch™, Bio-Rad CFX384 Touch™ and BioGX pixl.16 real-time PCR platforms. Nucleic acid extraction is not needed, and the lyophilized PCR reagents are simply rehydrated and patient sample is directly added. The fast and simple workflow is designed to help laboratories to increase their testing capacity without adding expert molecular staff or new automation.
* This product is for Research Use Only.
Acinetobacter baumannii, Klebsiella aerogenes/Enterobacter cloacae, Morganella morganii, Kingella kingae Part no. 450-041-Series
BioGX real-time PCR-based detection reagents are manufactured and packaged as open system reagents (OSR) for use with open system platforms and have to be validated by the user. Examples of open system platforms are the BD MAX™ System, Applied Biosystems QuantStudio™ 5, and Bio-Rad CFX96 Touch™ real-time PCR platforms.
Research use only reagents are not intended for human or animal diagnostic use. It is the responsibility of the end user to determine the performance of the reagents in an appropriately designed validation study for their intended use.
Bacteroides fragilis, Citrobacter freundii, Clostridium novyi/Clostridium septicum, Clostridium perfringens Part no. 450-042-Series
BioGX real-time PCR-based detection reagents are manufactured and packaged as open system reagents (OSR) for use with open system platforms and have to be validated by the user. Examples of open system platforms are the BD MAX™ System, Applied Biosystems QuantStudio™ 5, and Bio-Rad CFX96 Touch™ real-time PCR platforms.
Research use only reagents are not intended for human or animal diagnostic use. It is the responsibility of the end user to determine the performance of the reagents in an appropriately designed validation study for their intended use.
Candida auris Part no. 450-043-Series
BioGX real-time PCR-based detection reagents are manufactured and packaged as open system reagents (OSR) for use with open system platforms and have to be validated by the user. Examples of open system platforms are the BD MAX™ System, Applied Biosystems 7500 Fast Dx, QuantStudio™ 5, Bio-Rad CFX96 Touch™ and Bio-Rad CFX384 Touch™ real-time PCR platforms.
Research use only reagents are not intended for human or animal diagnostic use. It is the responsibility of the end user to determine the performance of the reagents in an appropriately designed validation study for their intended use.
Dermatophyte spp., Fungus spp., Trichophyton rubrum Part no. 450-048-Series
BioGX real-time PCR-based detection reagents are manufactured and packaged as open system reagents (OSR) for use with open system platforms and have to be validated by the user. Examples of open system platforms are the BD MAX™ System, Applied Biosystems QuantStudio™ 5, and Bio-Rad CFX96 Touch™ real-time PCR platforms.
Research use only reagents are not intended for human or animal diagnostic use. It is the responsibility of the end user to determine the performance of the reagents in an appropriately designed validation study for their intended use.
Enterococcus faecalis, Enterococcus faecium, Streptococcus pyogenes, Streptococcus agalactiae Part no. 450-044-Series
BioGX real-time PCR-based detection reagents are manufactured and packaged as open system reagents (OSR) for use with open system platforms and have to be validated by the user. Examples of open system platforms are the BD MAX™ System, Applied Biosystems QuantStudio™ 5, and Bio-Rad CFX96 Touch™ real-time PCR platforms.
Research use only reagents are not intended for human or animal diagnostic use. It is the responsibility of the end user to determine the performance of the reagents in an appropriately designed validation study for their intended use.
Escherichia coli, Klebsiella spp, Enterococcus faecalis, Streptococcus pyogenes Part no. 450-047-Series
BioGX real-time PCR-based detection reagents are manufactured and packaged as open system reagents (OSR) for use with open system platforms and have to be validated by the user. Examples of open system platforms are the BD MAX™ System, Applied Biosystems QuantStudio™ 5, and Bio-Rad CFX96 Touch™ real-time PCR platforms.
Research use only reagents are not intended for human or animal diagnostic use. It is the responsibility of the end user to determine the performance of the reagents in an appropriately designed validation study for their intended use.
Escherichia coli, Klebsiella spp., Pseudomonas aeruginosa, Proteus spp. Part no. 450-046-Series
BioGX real-time PCR-based detection reagents are manufactured and packaged as open system reagents (OSR) for use with open system platforms and have to be validated by the user. Examples of open system platforms are the BD MAX™ System, Applied Biosystems QuantStudio™ 5, and Bio-Rad CFX96 Touch™ real-time PCR platforms.
Research use only reagents are not intended for human or animal diagnostic use. It is the responsibility of the end user to determine the performance of the reagents in an appropriately designed validation study for their intended use.
Escherichia coli, Klebsiella spp., Staphylococcus saprophyticus, Enterococcus spp. Part no. 450-045-Series
BioGX real-time PCR-based detection reagents are manufactured and packaged as open system reagents (OSR) for use with open system platforms and have to be validated by the user. Examples of open system platforms are the BD MAX™ System, Applied Biosystems QuantStudio™ 5, and Bio-Rad CFX96 Touch™ real-time PCR platforms.
Research use only reagents are not intended for human or animal diagnostic use. It is the responsibility of the end user to determine the performance of the reagents in an appropriately designed validation study for their intended use.
Staphylococcus aureus, mecA, mecC, Streptococcus agalactiae Part no. 450-049-Series
BioGX real-time PCR-based detection reagents are manufactured and packaged as open system reagents (OSR) for use with open system platforms and have to be validated by the user. Examples of open system platforms are the BD MAX™ System, Applied Biosystems QuantStudio™ 5, and Bio-Rad CFX96 Touch™ real-time PCR platforms.
Research use only reagents are not intended for human or animal diagnostic use. It is the responsibility of the end user to determine the performance of the reagents in an appropriately designed validation study for their intended use.
Staphylococcus epidermidis group, Staphylococcus aureus, Staphylococcus lugdunensis, mecA Part no. 450-050-Series
BioGX real-time PCR-based detection reagents are manufactured and packaged as open system reagents (OSR) for use with open system platforms and have to be validated by the user. Examples of open system platforms are the BD MAX™ System, Applied Biosystems QuantStudio™ 5, and Bio-Rad CFX96 Touch™ real-time PCR platforms.
Research use only reagents are not intended for human or animal diagnostic use. It is the responsibility of the end user to determine the performance of the reagents in an appropriately designed validation study for their intended use.
Treponema pallidum Part no. 450-040-LMP
BioGX real-time PCR-based detection reagents are manufactured and packaged as open system reagents (OSR) for use with open system platforms and have to be validated by the user. Examples of open system platforms are the BD MAX™ System, Applied Biosystems 7500 Fast Dx, QuantStudio™ 5, Bio-Rad CFX96 Touch™ and Bio-Rad CFX384 Touch™ real-time PCR platforms.
Research use only reagents are not intended for human or animal diagnostic use. It is the responsibility of the end user to determine the performance of the reagents in an appropriately designed validation study for their intended use.
Acinetobacter baumannii, Morganella morganii, Escherichia coli Part no. 450-071-LMP
BioGX real-time PCR-based detection reagents are manufactured and packaged as open system reagents (OSR) for use with open system platforms and have to be validated by the user. Examples of open system platforms are Applied Biosystems QuantStudio™ 5, and Bio-Rad CFX96 Touch™ real-time PCR platforms.
Research use only reagents are not intended for human or animal diagnostic use. It is the responsibility of the end user to determine the performance of the reagents in an appropriately designed validation study for their intended use.
Klebsiella aerogenes, Enterobacter cloacae complex, Proteus vulgaris Part no. 450-072-LMP
BioGX real-time PCR-based detection reagents are manufactured and packaged as open system reagents (OSR) for use with open system platforms and have to be validated by the user. Examples of open system platforms are Applied Biosystems QuantStudio™ 5, and Bio-Rad CFX96 Touch™ real-time PCR platforms.
Research use only reagents are not intended for human or animal diagnostic use. It is the responsibility of the end user to determine the performance of the reagents in an appropriately designed validation study for their intended use.
Citrobacter freundii, Citrobacter koseri, Salmonella spp. Part no. 450-073-LMP
BioGX real-time PCR-based detection reagents are manufactured and packaged as open system reagents (OSR) for use with open system platforms and have to be validated by the user. Examples of open system platforms are Applied Biosystems QuantStudio™ 5, and Bio-Rad CFX96 Touch™ real-time PCR platforms.
Research use only reagents are not intended for human or animal diagnostic use. It is the responsibility of the end user to determine the performance of the reagents in an appropriately designed validation study for their intended use.
Klebsiella oxytoca, Klebsiella pneumoniae, Pseudomonas aeruginosa Part no. 450-074-LMP
BioGX real-time PCR-based detection reagents are manufactured and packaged as open system reagents (OSR) for use with open system platforms and have to be validated by the user. Examples of open system platforms are Applied Biosystems QuantStudio™ 5, and Bio-Rad CFX96 Touch™ real-time PCR platforms.
Research use only reagents are not intended for human or animal diagnostic use. It is the responsibility of the end user to determine the performance of the reagents in an appropriately designed validation study for their intended use.
Proteus mirabilis, Providencia stuartii, Serratia marcescens Part no. 450-075-LMP
BioGX real-time PCR-based detection reagents are manufactured and packaged as open system reagents (OSR) for use with open system platforms and have to be validated by the user. Examples of open system platforms are Applied Biosystems QuantStudio™ 5, and Bio-Rad CFX96 Touch™ real-time PCR platforms.
Research use only reagents are not intended for human or animal diagnostic use. It is the responsibility of the end user to determine the performance of the reagents in an appropriately designed validation study for their intended use.
Staphylococcus aureus, Staphylococcus lugdunensis, Staphylococcus saprophyticus Part no. 450-076-LMP
BioGX real-time PCR-based detection reagents are manufactured and packaged as open system reagents (OSR) for use with open system platforms and have to be validated by the user. Examples of open system platforms are Applied Biosystems QuantStudio™ 5, and Bio-Rad CFX96 Touch™ real-time PCR platforms.
Research use only reagents are not intended for human or animal diagnostic use. It is the responsibility of the end user to determine the performance of the reagents in an appropriately designed validation study for their intended use.
Staphylococcus epidermidis, Staphylococcus haemolyticus, Streptococcus agalactiae Part no. 450-077-LMP
BioGX real-time PCR-based detection reagents are manufactured and packaged as open system reagents (OSR) for use with open system platforms and have to be validated by the user. Examples of open system platforms are Applied Biosystems QuantStudio™ 5, and Bio-Rad CFX96 Touch™ real-time PCR platforms.
Research use only reagents are not intended for human or animal diagnostic use. It is the responsibility of the end user to determine the performance of the reagents in an appropriately designed validation study for their intended use.
Gardnerella vaginalis, Trichomonas vaginalis, Candida spp. Part no. 450-078-LMP
BioGX real-time PCR-based detection reagents are manufactured and packaged as open system reagents (OSR) for use with open system platforms and have to be validated by the user. Examples of open system platforms are Applied Biosystems QuantStudio™ 5, and Bio-Rad CFX96 Touch™ real-time PCR platforms.
Research use only reagents are not intended for human or animal diagnostic use. It is the responsibility of the end user to determine the performance of the reagents in an appropriately designed validation study for their intended use.
HSV-1 and HSV-2 Part no. 450-079-LMP
BioGX real-time PCR-based detection reagents are manufactured and packaged as open system reagents (OSR) for use with open system platforms and have to be validated by the user. Examples of open system platforms are Applied Biosystems QuantStudio™ 5, and Bio-Rad CFX96 Touch™ real-time PCR platforms.
Research use only reagents are not intended for human or animal diagnostic use. It is the responsibility of the end user to determine the performance of the reagents in an appropriately designed validation study for their intended use.
Chlamydia trachomatis, Neisseria gonorrhoeae, Enterococcus faecalis Part no. 450-080-LMP
BioGX real-time PCR-based detection reagents are manufactured and packaged as open system reagents (OSR) for use with open system platforms and have to be validated by the user. Examples of open system platforms are Applied Biosystems QuantStudio™ 5, and Bio-Rad CFX96 Touch™ real-time PCR platforms.
Research use only reagents are not intended for human or animal diagnostic use. It is the responsibility of the end user to determine the performance of the reagents in an appropriately designed validation study for their intended use.
Mycoplasma genitalium, Mycoplasma hominis, Ureaplasma spp. Part no. 450-087-LMP
BioGX real-time PCR-based detection reagents are manufactured and packaged as open system reagents (OSR) for use with open system platforms and have to be validated by the user. Examples of open system platforms are Applied Biosystems QuantStudio™ 5, and Bio-Rad CFX96 Touch™ real-time PCR platforms.
Research use only reagents are not intended for human or animal diagnostic use. It is the responsibility of the end user to determine the performance of the reagents in an appropriately designed validation study for their intended use.
Chlamydia trachomatis, Neisseria gonorrhoeae, Trichomonas vaginalis Part no. 450-088-LMP
BioGX real-time PCR-based detection reagents are manufactured and packaged as open system reagents (OSR) for use with open system platforms and have to be validated by the user. Examples of open system platforms are Applied Biosystems QuantStudio™ 5, and Bio-Rad CFX96 Touch™ real-time PCR platforms.
Research use only reagents are not intended for human or animal diagnostic use. It is the responsibility of the end user to determine the performance of the reagents in an appropriately designed validation study for their intended use.
Candida albicans, Candida glabrata, Candida krusei, Trichomonas vaginalis Part no. 450-035-Series
BioGX real-time PCR-based detection reagents are manufactured and packaged as open system reagents (OSR) for use with open system platforms and have to be validated by the user. Examples of open system platforms are the BD MAX™ System, Applied Biosystems QuantStudio™ 5, and Bio-Rad CFX96 Touch™ real-time PCR platforms.
Research use only reagents are not intended for human or animal diagnostic use. It is the responsibility of the end user to determine the performance of the reagents in an appropriately designed validation study for their intended use.
Xfree™ HSV-1, HSV-2, VZV Open System PCR Reagents Part no. 450-030-E-PXL
The BioGX Xfree™ HSV-1, HSV-2, VZV PCR Assay is offered in the lyophilized “Just Add Sample” format within single PCR tubes where no other reagent is required. The test is available for BioGX pixl.16 real-time PCR instrument. Nucleic acid extraction is not needed, and the lyophilized PCR reagents are simply rehydrated and patient sample is directly added. The fast and simple workflow is designed to help laboratories to increase their testing capacity without adding expert molecular staff or new automation.
* This product is for Research Use Only.
Xfree™ Treponema pallidum Open System PCR Reagents Part no. 450-040-E-PXL
The BioGX Xfree™ Treponema pallidum PCR Assay is offered in the lyophilized “Just Add Sample” format within single PCR tubes where no other reagent is required. The test is available for BioGX pixl.16 real-time PCR instrument. Nucleic acid extraction is not needed, and the lyophilized PCR reagents are simply rehydrated and patient sample is directly added. The fast and simple workflow is designed to help laboratories to increase their testing capacity without adding expert molecular staff or new automation.
* This product is for Research Use Only.
Xfree™ hMPXV Open System PCR Reagents Part no. 450-086-E-PXL
The BioGX Xfree™ hMPXV PCR Assay is offered in the lyophilized “Just Add Sample” format within single PCR tubes where no other reagent is required. The test is available for BioGX pixl.16 real-time PCR instrument. Nucleic acid extraction is not needed, and the lyophilized PCR reagents are simply rehydrated and patient sample is directly added. The fast and simple workflow is designed to help laboratories to increase their testing capacity without adding expert molecular staff or new automation.
* This product is for Research Use Only.
Gardnerella vaginalis, Trichomonas vaginalis, Candida albicans, Candida glabrata Part no. 450-037-Series
BioGX real-time PCR-based detection reagents are manufactured and packaged as open system reagents (OSR) for use with open system platforms and have to be validated by the user. Examples of open system platforms are the BD MAX™ System, Applied Biosystems QuantStudio™ 5, and Bio-Rad CFX96 Touch™ real-time PCR platforms.
Research use only reagents are not intended for human or animal diagnostic use. It is the responsibility of the end user to determine the performance of the reagents in an appropriately designed validation study for their intended use.
HSV-1, HSV-2, Haemophilus ducreyi Part no. 450-038-Series
BioGX real-time PCR-based detection reagents are manufactured and packaged as open system reagents (OSR) for use with open system platforms and have to be validated by the user. Examples of open system platforms are the BD MAX™ System, Applied Biosystems QuantStudio™ 5, and Bio-Rad CFX96 Touch™ real-time PCR platforms.
Research use only reagents are not intended for human or animal diagnostic use. It is the responsibility of the end user to determine the performance of the reagents in an appropriately designed validation study for their intended use.
Mycoplasma genitalium, M. hominis, Ureaplasma urealyticum, U. parvum Part no. 450-039-C-MAX
BioGX real-time PCR-based detection reagents are manufactured and packaged as open system reagents (OSR) for use with open system platforms and have to be validated by the user. Examples of open system platforms are the BD MAX™ System.
Research use only reagents are not intended for human or animal diagnostic use. It is the responsibility of the end user to determine the performance of the reagents in an appropriately designed validation study for their intended use.
Treponema pallidum Part no. 450-040-Series
BioGX real-time PCR-based detection reagents are manufactured and packaged as open system reagents (OSR) for use with open system platforms and have to be validated by the user. Examples of open system platforms are the BD MAX™ System, Applied Biosystems 7500 Fast Dx, QuantStudio™ 5, Bio-Rad CFX96 Touch™ and Bio-Rad CFX384 Touch™ real-time PCR platforms.
Research use only reagents are not intended for human or animal diagnostic use. It is the responsibility of the end user to determine the performance of the reagents in an appropriately designed validation study for their intended use.
Atopobium vaginae, Mobiluncus curtisii, Mobiluncus mulieris, Prevotella bivia Part no. 450-034-Series
BioGX real-time PCR-based detection reagents are manufactured and packaged as open system reagents (OSR) for use with open system platforms and have to be validated by the user. Examples of open system platforms are the BD MAX™ System, Applied Biosystems QuantStudio™ 5, and Bio-Rad CFX96 Touch™ real-time PCR platforms.
Research use only reagents are not intended for human or animal diagnostic use. It is the responsibility of the end user to determine the performance of the reagents in an appropriately designed validation study for their intended use.
Candida albicans, Candida glabrata, Candida tropicalis/Candida parapsilosis, Candida krusei Part no. 450-036-Series
BioGX real-time PCR-based detection reagents are manufactured and packaged as open system reagents (OSR) for use with open system platforms and have to be validated by the user. Examples of open system platforms are the BD MAX™ System, Applied Biosystems QuantStudio™ 5, and Bio-Rad CFX96 Touch™ real-time PCR platforms.
Research use only reagents are not intended for human or animal diagnostic use. It is the responsibility of the end user to determine the performance of the reagents in an appropriately designed validation study for their intended use.
450-051-XMM
The BioGX Xfree DNA Master Mix real-time PCR-based detection reagent is manufactured and packaged as an open system reagent (OSR) for use with open system platforms and has to be validated by the user. Examples of open system platforms are the Applied Biosystems, QuantStudio™ 5 and ABI 7500 Fast Dx real-time PCR platforms.
Research use only reagents are not intended for human or animal diagnostic use. It is the responsibility of the end user to determine the performance of the reagents in an appropriately designed validation study for their intended use.
Subscribe and Learn
Dr. Martinez joined BioGX in 2015. Dr. Martinez is responsible for Business Development and Scientific Affairs, expanding our portfolio of IVD products, managing the global technical support efforts of all molecular diagnostic products, and manages a team of scientists responsible for product and technology innovation in conjunction with existing corporate partnerships. Dr. Martinez has over 20 years of experience in molecular biology. Prior to joining BioGX, Dr. Martinez held research positions focusing on cancer cell biology at Albany Medical College, microbial community dynamics at The Georgia Institute of Technology and microbial physiology at The University of Alabama. Dr. Martinez holds a BA in Biology from Boston University and a Ph.D. in Microbiology from The Georgia Institute of Technology.
Mr. Green joined BioGX as a Controller in 2020. He has 30+ years of leadership experience in accounting across diverse industries, including healthcare, water utility management, waste management, mineral extraction, and cash handling. At BioGX, Mr. Green is responsible for managing finance and purchasing departments. He has a BS degree in Accounting from The University of Alabama, and he is a Certified Public Accountant (inactive).
Dr. Shazi Iqbal is a Co-Founder of BioGX and served as its CEO from 2011 to June 2024. Now, as a Venture Partner, he leads M&A and strategic investment opportunities to enable innovation partnerships. Dr. Iqbal has over 25+ years of experience in building healthcare startups into profitable growth companies. He holds a Ph.D. in Biology (Neuroscience), two M.S. degrees in Biochemistry & Biotechnology, and several patents and publications.
Targets |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Bacteria | Viruses | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
Dr. Shahin Iqbal is the President and Chief Operating Officer at BioGX. He has over 25 years of experience in clinical molecular diagnostics. Before joining BioGX, Dr. Iqbal led the Abbott Diagnostics Global Service & Support specifically for informatics, core lab automation, immunoassay and clinical chemistry systems. He was also responsible for design and development of FISH automation systems at Abbott Molecular. He is the recipient of the President awards and multiple service & innovation awards at Abbott. Dr. Iqbal holds multiple patents on optical sensors, automation systems development, RFID applications and robotics for system dispensing. Prior to joining Abbott, Dr. Iqbal was Head of operations, quality & regulatory, systems development and manufacturing of IHC systems at BioGenex in California. Dr. Iqbal has an MBA and Ph.D as well as a Masters in Electrical Engineering degree from the University of Texas in San Antonio.
Mr. Blackstone joined BioGX in 2007. He has served at BioGX in various senior R&D and quality management roles prior to his current position as VP of Research & Development. Mr. Blackstone has designed and directed the development of over 100 multiplex real time PCR products in the fields of food safety, water quality, pharma QC, and clinical diagnostics. Mr. Blackstone previously served for eight years at the US Food and Drug Administration and as a Commissioned Research Officer in the US Public Health Service Commissioned Corps where he achieved the rank of Lieutenant Commander. George Blackstone received his Master of Science degree from Louisiana State University.
Mr. Hughes joined BioGX in 2015. Prior to joining BioGX, Mr. Hughes led efforts for a diverse range of companies with the development and implementation of certified quality management systems ranging from data storage devices with SONY Corporation, security & detention devices with Norment Security Group, textile manufacturing with Twitchell Corporation, combat vehicle manufacturing with General Dynamics, and therapeutic medical devices with Steris Corporation. Christopher has a BSE from Auburn University and an MBA from Troy State University.
If you are contacting us because you have received a phone call offering genetic testing services, with the caller requesting personal health information and personal identification numbers (such as Medicare Card numbers), please know that we are NOT responsible for such calls.
We, BioGX, Inc., (registered trademark “BioGX”) with offices in Birmingham, AL, Dallas, TX, and Amsterdam, The Netherlands, are a diagnostic test manufacturer and not a testing laboratory, and we are not in any way affiliated with such callers. We do not know who is making these calls.
UNDER NO CIRCUMSTANCES BIOGX WOULD EVER CONTACT INDIVIDUALS TO OFFER GENETIC TESTING SERVICES OR REQUEST PERSONAL INFORMATION OF ANY KIND.
This Fact Sheet informs you of the significant known and potential risks and benefits of the use of the BioGX Xfree™ COVID-19 Direct RT-PCR.
The BioGX Xfree™ COVID-19 Direct RT-PCR is validated for use with respiratory specimens collected from individuals suspected of COVID-19 by their healthcare provider.
QuantStudio™ 5 Direct Sample Run File
QuantStudio™ 5 Direct Sample PDF
CFX96 Touch™ Direct Sample Run File 1
CFX96 Touch™ Direct Sample Run File 2
CFX96 Touch™ Direct Sample PDF
Dr. Vickery founded BioGX in 2007 and served as President and CEO until 2011. Prior to founding BioGX, Dr. Vickery worked in sales and as a technical consultant at Cepheid. Prior to Cepheid, Dr. Vickery worked at the FDA as a University of Maryland JIFSAN postdoctoral fellow at the University of Maryland, and later served as the Lead for Molecular Methods Development at the U.S. FDA Gulf Coast Seafood Laboratory. He holds multiple patents in biotechnology, has authored or co-authored many publications, and has extensive experience in gene expression analysis, and in the design and development of rapid multiplex molecular tests for microbial and viral detection. Dr. Vickery holds a B.S. degree in Physics and both M.S. and Ph.D. degrees in Biology (molecular biology and molecular genetics focus – both prokaryotic and eukaryotic). Prior to entering graduate school, Dr. Vickery worked as an executive in the lowbed trailer industry for almost 10 years, pioneering the sale of American made heavy equipment transport trailers into China (ROC) and Japan during his tenure in the industry, and resupplying the oilfields of Kuwait with specialized trailers after the Gulf War.